⌘K
Attached footage · 3 clips
All from Park Centre · 02:38 → 02:46
CAM-01 · 02:41:18
Tills row · person approaches
14s · 1080p
CAM-02 · 02:39:42
Entrance N · door event
22s · 1080p
CAM-09 · 02:14:00
Stockroom rear · last frame
Offline since · power loop
Activity timeline
System events + operator notes
02:14:00
CAM-09 (Stockroom rear) went offline
No heartbeat from NVR. Suspected mains breaker — overnight stand-by tripped at 02:13:58 (Stanbic UPS log).
02:39:42
Door sensor · entrance N opened
Magnetic contact triggered. Alarm panel armed in "perimeter" mode — did not raise siren because user code 0042 (cleaner) was entered at 02:39:30.
02:41:18
Motion alert · CAM-01 tills row
Auto-anchor written. Severity: High (after-hours zone). Routed to on-call: S. Oliver.
02:43:02
S. Oliver opened the incident
Notes: "Looks like Faith Moyo — she has a cleaning shift starting 02:30 on Mondays. Verifying with her supervisor."
05:12:04
Cleaner sign-out logged
Card swipe · Faith Moyo · entrance N · cleaning crew sheet attached.
08:18:30
T. Chigumba (HR) confirmed cleaning shift
"Faith Moyo is on cleaning rota for Mondays 02:30 – 05:00 — added to roster yesterday but security profile wasn't synced. Fix queued."
08:21:14
Note · S. Oliver
Recommend closing with reason "false-positive · roster sync"; raise maintenance ticket for CAM-09 power loop separately.
Incident facts
| Ref | INC-2026-0218 |
| Site | Park Centre · Harare |
| Camera | CAM-01 Tills row |
| Detected | Mon 22 Jun 02:41:18 |
| Severity | High |
| Status | In review |
| Assigned | S. Oliver |
| Reported by | Auto · motion zone "tills" |
| Linked WO | WO-2026-0184 · CAM-09 power |
Attachments
3 clips · 1 log · 1 photo
| Clip | cam01_0241.mp4 14s · 4.2 MB | |
| Clip | cam02_0239.mp4 22s · 6.8 MB | |
| Clip | cam09_offline.mp4 last 8s · 2.1 MB | |
| Log | alarm-panel-022026.csv 12 events · 02:00 → 06:00 | |
| Photo | cleaning-rota-jun.jpg From T. Chigumba |